Brief introduction
Skin sensor utilises two independent thermistors that are continuously compared to ensure accuracy and safety in temperature control. The DuoSense has a strong but flexible cable with triple kevlar stranding for extended durability.
Specification:
Reusable medical temperature probe
Included with baby Controlled Warmers (IW910, IW931, IW932, IW934 and IW980)
The SureSense is a single patient use temperature sensor designed for accurate temperature measurement with a thermistor accuracy of ±0.1ºC.
The DaisyDot covers are single baby multi-use items, with reflective and insulative properties to protect the skin sensor from external sources of heat. The petal design minimises sensor cover lift while providing an exit points for the sensor cable.
The reusable adaptor for the single use temperature sensor, SureSense is designed with a leash to prevent the adaptor from becoming dislodged from the Fisher & Paykel Healthcare infant warmers.
With the development of monitoring technology and the development of body temperature research, people in clinical anesthesia work more and more attention to the body temperature index.
Product name |
Skin Sensor Human body surface temperature probe NTC thermistor |
Ended connector |
3.5 mono plug P2 |
Probes |
Dial adult: 12mm; Children: 9.5 mm |
Feature |
Accurate temperature measurement in 3s. |
Length |
500mm~ 4500mm |
Resistance value |
2.252kΩ/10kΩ |
Compatible for all YSl 400 series monitor devices. For example GE, HP, Nihon Kohden, Philips, Siemens, Mindray, Edan, Biolight etc. Standard resistance 10kΩ and 2.252kΩ,standard precision (25~45) ºC ± 0.1ºC(Other resistance or precision requirement can be customized.)
Customized temperature measurement 0.1C 2.25K body medical temperature sensor
You may also like these products:
Advantages as below:
Temp Accuracy: NovaMed baby-sensitive thermistor sensor guarantees temperature reading sensitivity with a stable, highly accurate measurement.
Molded Plug assembly provides direct connection to the GIRAFFE incubator / radiant warmer.
Sensor safety: Flexible lead wire facilities sensor placement on the infant eliminating the need for interface / interconnector cable, ensuring precision and safety.
Ease of Use: Packaged individually in a Tyvek pouch with an insulated adhesive Mylar temperature probe cover (one inch circular disk).
Gentle: Neonatal sensitive hypoallergenic adhesive /reflective Mylar probe cover provides insulation from heat and external sources while further ensuring precise temperature monitoring capabilities.