• Resusable Skin Temperature Probe Medical Thermistor Sensor, 3.5mm Phone Right Angled Plug to 5.8mm Disk Sensor
  • Resusable Skin Temperature Probe Medical Thermistor Sensor, 3.5mm Phone Right Angled Plug to 5.8mm Disk Sensor
  • Resusable Skin Temperature Probe Medical Thermistor Sensor, 3.5mm Phone Right Angled Plug to 5.8mm Disk Sensor
  • Resusable Skin Temperature Probe Medical Thermistor Sensor, 3.5mm Phone Right Angled Plug to 5.8mm Disk Sensor
  • Resusable Skin Temperature Probe Medical Thermistor Sensor, 3.5mm Phone Right Angled Plug to 5.8mm Disk Sensor
  • Resusable Skin Temperature Probe Medical Thermistor Sensor, 3.5mm Phone Right Angled Plug to 5.8mm Disk Sensor

Resusable Skin Temperature Probe Medical Thermistor Sensor, 3.5mm Phone Right Angled Plug to 5.8mm Disk Sensor

Customized: Customized
Certification: CE, ISO13485, RoHS
Scale: Small
Resistance: Custom
Beta Value: Custom
Application: Temperature Measurement
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Anhui, China
to see all verified strength labels (21)

Basic Info.

Model NO.
JP402
Brand
Jingpu Sensor
Transport Package
Neutral Packing
Specification
Ф 5.8mm
Trademark
J. P. Sensor
Origin
Hefei, Anhui, China
HS Code
9025199090
Production Capacity
50000PCS/Year

Product Description

Specification:
 Resusable Skin Temperature Probe Medical thermistor sensor,3.5mm Phone right angled plug to 5.8mm disk sensor. It's one NTC type thermistor sensor. NTC is an acronym for Negative Temperature Coefficient. Jingpu is a leading designer and manufacturer of high precision discrete NTC thermistors, probes and assemblies. An NTC thermistor is a temperature sensor that uses the resistance properties of ceramic/metal composites to measure the temperature. Our full spectrum NTC sensors offer many advantages in temperature sensing including miniature size, excellent long-term stability, high accuray and precision.

Drawing as below:
Resusable Skin Temperature Probe Medical Thermistor Sensor, 3.5mm Phone Right Angled Plug to 5.8mm Disk Sensor

  Body temperature is one of the main vital signs of the human body. Human body temperature to be maintained at 37 ºC basically stable, in order to ensure the normal operation of metabolism and other functions, which is the common characteristics of all mammals.
  With the development of monitoring technology and the development of body temperature research, people in clinical anesthesia work more and more attention to the body temperature index.
Product name  Resusable skin temperature probe
Ended connector 3.5mm mono plug
Probes Dial adult: 12mm; Children:5.8 mm
Feature Accurate temperature measurement in 3s.
Length 500mm~ 4500mm
Resistance value 2.252kΩ/10kΩ
Lead-free Yes Cable Jacket TPU
Latex-Free Yes Over-Mold PVC
Blocompatible Yes Sensor Size Ф5.8 Disk
RoHS Compliant Yes Connector Ф3.5 plug
 Compatible for all YSl 400 series monitor devices. For example GE, HP, Nihon Kohden, Philips, Siemens, Mindray, Edan, Biolight etc. Standard resistance 10kΩ and 2.252kΩ,standard precision (25~45) ºC ± 0.1ºC(Other resistance or precision requirement can be customized.)
  Customized temperature measurement 0.1C 2.25K body medical temperature sensor

Reliability test
High temperature Exposure (Storage) - Resistance (R25) change should be less than ±5%.
- B-constant (B25/50) change should be less than ±2%.
- No visible damage.
Leave continuously according to the following table for 1000 hours.
Operating Temp. Range: -40 to +150ºC Type 150±3ºC
Operating Temp. Range: -40 to +125ºC Type 125±3ºC
Measurement at 24±2 hours after test condition.
Temperature Cycling - Resistance (R25) change should be less than ±5%.
- B-constant(B25/50) change should be less than ±2%.
- No visible damage
Perform 1000 cycles according to the four heat treatments listed in the following table.
Step 1 2 3 4
Temp.(deg.C) -55+0/-3 Room Temp. 125+3/-0 Room Temp.
Time (min.) 15±3 1 15±3 1
Measurement at 24±2 hours after test condition.
Moisture Resistance - Resistance(R25) change should be less than ±5%.
- B-constant(B25/50) change should be less than ±2%.
- No visible damage.
Apply the 24-hour heat (25 to 65ºC) and humidity (80 to 98%) treatment shown below, 10 consecutive times. Measurement at 24±2 hours after test condition.
Biased Humidity - Resistance (R25) change should be less than ±10%
- B-constant(B25/50) change should be less than ±2%
- No visible damage.
85±2ºC, 85%RH in air for 1000 hours with Permissive Operating Current. Measurement at 24±2 hours after test conditions
Operational Life - Resistance(R25) change should be less than ±5%
- B-constant (B25/50) change should be less than ±2%
- No visible damage
85±3ºC in air for 1000 hours with Permissive Operating Current. Measurement at 24±2 hours after test conditions
External Visual No defects of abnormalities Visual Inspection.
Physical Dimension Within the specified dimensions Using calipers





 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
5000000 RMB
Management System Certification
ISO 9001, ISO 13485